P.F. Compensator- Automatic P.F. Correction Series - 12.5 KVAR to 100 KVAR

Features :

NAAC P.F. Compensator series the power range goes from 12.5 kvar to 100 kvar. They are designed for small to medium load networks. They are highly reliable, cost effective solution for maintaining high network power factor.

They are ultimate solution for compensation of unbalanced loads. The compensation is released by measuring the reactive power of the system, through 3 CTs from all 3 phases. This makes it best suited even for most unbalanced loads apart from balanced loads.

They come equipped with following outstanding features:

  • Incomer TP MCCB 35kA

  • Micro processor based Neptune Phasetrac range of 3 phase P.F. Controller

  • Inbuilt 3 phase Analyzer

  • Compact wall mounting series with zinc passivated side clamps

  • Front louvers with Axial Flow Fan & Thermostat

  • Heavy Duty specially designed Neptune Capacitor Duty Contactors with high thermal current withstand capacity.

  • MCBs for control circuit protection

  • HRC Fuse or MCB (Series-D) for backup protection of capacitor banks.

  • High electrolytic grade Aluminium Busbar installed on SMC TP supports.

  • Discharge resistors (MOR)

  • Standard 1 Year warranty with NSL-10 Capacitor or 3 Year warranty with Long Life LL-10 Mono16 Capacitors.

  • Powder Coated- RAL 7035, Structure Finish


Advanced 3 Phase Control Module

Controller

Control Module with Data Logger

  • Measurement of A, V, PF, Cosφ, W, VAR, VA (ΣW, ΣVA, Σvar etc.)

  • Sense 1% of load current.

  • Auto/Manual mode selection with indicator light.

  • Automatic calculation of C/k value.

  • Program entry for targeted Cosφ value.

  • Number of capacitor steps are user definable.

  • The consequent switching time between capacitor steps is adjustable from 2 to 50 seconds.

  • C+/NORMAL/C- condition lights indicate actual system state.

  • Over Voltage, Insufficient Compensation, Over Compensation state, alarm indicator lights with output contact.

  • Adjustable programmable Over Voltage protection for capacitor banks.

  • Micro Controller based digital design complying with international standards.

  • Flush mounting with rear panel connectors.

  • Designed to use with Current Transformer (.../5A).

Electrical & General Characteristics:

  • Power range: 12.5 - 100 KVAR (440V)

  • Mains voltage (working voltage): standard 440V (other voltage on request)

  • Rated frequency :50 Hz

  • Altitude: 2000 m a.s.l.

  • Relative humidity: 90% max. at 35ºC

  • Duty :continuous

  • Temperature class:-25+ 55ºC

  • Power supply line: Three-phase + ground + neutral (for 440V mains version only)

  • Relay current input signal: from CT on line.../5A

  • Relay voltage input signal: picked up internally.

Installation 

  • Indoors, wall-mounted, in ventilated, non-dusty environment, away from direct sunlight.

  • Cable inlet from top

Disconnecting Switch

  • TP MCCB - 35 kA breaking capacity.

Mechanical Structure

  • The basic structure is made of white CRCA steel sheet with mounting plate Zinc galvanized.

  • The outer steel structural work is painted with cleaning treatment, degreasing, phosphating 70mm thickness paint with epoxy powder colour RAL7035.

  • Louvers on front door with Axial Flow Fan.

  • Capacitor mounted on side openable section from outside - offering easy replacement.

Wiring & Busbar

  • HR Copper wires are used for all the wiring connecting to Electrolytic grade Cu./Al. Busbar section.

Fuses / MCBs for Backup protection

  • HRC Fuse Link with base

  • The fuses are of 80kA breaking capacity.

  • Series-D TP MCBs for backup protection (optional)

Contactors

  • Equipped with Heavy Duty Capacitor Duty Contactor with early make contacts.

  • Coil voltage 230V, 50-60Hz.

Capacitors

  • Series NSL-10 Floppy Cap single-ph. elements wired in a delta connection rated 450V.

  • Optionally Long Life LL-10 Mono16 Series Capacitors, rated 450V.

Protection Devices

  • Each capacitor bank is equipped with discharge devices capable of reducing the residual voltage to below 10% of the rated capacitor voltage in about 30 seconds.

Screening Inspection 100%

Each automatic system manufactured undergoes the following tests & inspections:

  • Visual and dimensional inspection.

  • Check on mechanical efficiency.

  • Insulation test, 2.5kV for 1 min., between phases and ground.

  • Check on electrical efficiency at 440V, with verification of the total capacitance of the capacitors installed in the system.

Dimension



Rating 440V,
50Hz
vItem Code

Capacitor Power at Un

10 20 30 40 50
KVAR KVAR KVAR KVAR KVAR
In(A)

Main Switch

A

Icc(kA)

Size
12.5 PFC-12.5 A 2.5 5 5     16.3 32 35 A
17.5 PFC-17.5-A 2.5 5 10     22.9 32 35 A
18 PFC-18-A 3.75 7.5 7.5     23.5 32 35 A
20 PFC-20-A 5 5 10     26.2 50 35 A
22 PFC-22-A 3.125 6.25 12.5     28.8 50 35 A
25 PFC-25-A 5 10 10     32.7 50 35 A
30 PFC-30-A 5 5 10 10   39.3 63 35 A
31 PFC-31-A 6.25 12.5 12.5     40.6 63 35 A
35 PFC-35-A 5 10 20     45.8 63 35 A
40 PFC-40-A 10 10 10 10   52.4 100 35 A
44 PFC-44-A 6.25 12.5 25     57.6 100 35 A
47 PFC-47-A 3.125 6.25 12.5 25   61.5 100 35 A
50 PFC-50-1-A 10 20 20     65.5 100 35 A
50 PFC-50-2-A 12.5 12.5 12.5 12.5   65.5 100 35 A
56 PFC-56-B 6.25 12.5 12.5 12.5 12.5 73.3 100 35 B
62.5 PFC-62.5-A 12.5 25 25     81.8 125 35 A
68 PFC-68-B 6.25 12.5 25 25   89 125 35 B
75 PFC-75-B 12.5 12.5 25 25   98.2 125 35 B
81.25 PFC-81.25-B 6.25 12.5 12.5 25 25 106.4 160 35 B
87.5 PFC-87.5-B 12.5 25 25 25   114.6 160 35 B
93.75 PFC-93.75-B 6.25 12.5 25 25 25 122.8 160 35 B
100 PFC-100-B 12.5 12.5 25 25 25 131 160 35 B

Suffix Item Code with following Type nos.:

Type-1 - NSL-10 with HRC Fuses as backup protection
Type-2 - NSL-10 with MCB as backup protection
Type-3 - LL-10 with HRC Fuses as backup protection
Type-4 - LL-10 with MCB as backup protection
Size A : 700mm (W) x 275mm (D) x 700mm (H)